Online Alışveriş Sitemize Hoşgeldiniz.

0(216) 466 41 47
0(530) 265 13 93

Cart:

0 item(s) - 0,00 TL
Sepetinizde hiç ürün yok.

0

Diğer Görünümler

MultiCon CMC I/O modules M99-FI2-001

Durumu: stokta mevcut

Only 2 left

175,00 TL

Hızlı Gözat

ÜRÜN AÇIKLAMASI : ÜRÜN SIFIR AMBALAJINDADIR

Detaylar

MultiCon CMC I/O modules M99-FI2-001 Input modules - analogue flow meters FI2: 2 analogue flow meters + 2 current inputs The FI modules have been especially designed for the MultiCon units used in flow measurement applications. They allow user to display and record both actual flow (rate) and total flow (volume). These modules have extra 2 or 4 analogue inputs for general purpose use. Each flow channel is equipped with IN[n]input and common ground GND. All inputs are galvanically separated from the device, however have common ground. The user can, thanks to Scaling parameter in Logical channel, interpret measured current by the device at its discretion, which allows to cooperate with any kind of analogue output sensors. The general purpose use current inputs have common ground and they are isolated from the supply voltage and other modules. Analogue flowmeter parameters are: - Name - read-only input name given by the device, - Unit - read-only field which displays measurement unit, - Base unit - defines unit which is used by the totalizer (for example when flow measurement unit is m3/s, the base unit is „m3”) , - Mode - defines current range of selected input (0÷20 mA, 4÷20 mA) and the time base which is used during the measurement, - Low limit - value which determines measured current, below which in logical channel „Lo” state will be displayed, - High limit - value which determines measured current, above which in logical channel „Hi” state will be displayed, - Balance- submenu which contains totalizer settings: ź Reset now- manual reset of the totalizer, ź Reset mode- turns on and off reset from logical channel, ź Reset source- allows to choose a logical channel from the list, which will reset the totalizer, when value in this channel will be greater than 0, ź Strobe mode- turns on and off balance calculating from logical channel, ź Strobe source- allows to choose logical channel from the list, which will hold balance calculating in totalizer, ź Counting direction- turns on and off change of the counting direction, ź Direction source- allows to choose a logical channel from the list, which will change the counting direction. TECHNICAL DATA Number of inputs : 2 x analogue flowmeter + 2 x current Measurement range : flow input modes: 0 ÷ 20 mA, 4 ÷ 20 mA flow input units: 1/sec, 1/min, 1/h current input: 0 ÷ 20 mA, 4 ÷ 20 mA Hardware limitation : current: -2 mA ÷ 30 mA Hardware resolution : current: 1 µA Precision : 0.25% @ 25°C Internal impedance : current: typ. 100 Ω Protection current : 50 mA, auto-reset fuse Sampling period : 10 ms (CMC reads modules every 100 ms) Part number : M99-FI2-001

Ek Bilgi

Ürün Kodu GM-1800/4

Ürün Etiketleri

Etiketleri ayırmak için boşluk kullanınız. Deyim tipindeki etiketler için tekli tırnak (') kullanınız.