Online Alışveriş Sitemize Hoşgeldiniz.

0(216) 466 41 47
0(530) 265 13 93

Cart:

0 item(s) - 0,00 TL
Sepetinizde hiç ürün yok.

0

Diğer Görünümler

MultiCon CMC I/O Modules M99-FT2-001

Durumu: stokta mevcut

Only 2 left

175,00 TL

Hızlı Gözat

ÜRÜN AÇIKLAMASI : ÜRÜN SIFIR AMBALAJINDADIR

Detaylar

MultiCon CMC I/O Modules FT2 Input modules - pulse flow or ratemeters FT2: 2 isolated pulse flow or ratemeters + 2 current inputs The FTmodules have been especially designed for the MultiCon units used in flow or rate measurement applications. They allow user to display and record both actual flow (rate) and total flow (volume). These modules have extra 2 or 4 analogue inputs for general purpose use. Each pulse channel is equipped with counting inputs: Inp[n]1, Inp[n]2 and common ground COM[n]. All pulse channels are galvanically separated from the device and from themselves. The general purpose use current inputs have common ground and they are isolated from the supply voltage and other modules. FT2 and FT4 modules can be used also as high speed quadrature counters. Pulse flow or ratemeters parameters are: - Name - read-only input name given by the device, - Unit - read-only field which displays the time base of the measurement, - Base unit - defines unit which is used by the totalizer (for example when flow measurement unit is m3/s, the base unit is „m3”) , - Mode - defines the time base which is used during the measurement (pulses per second, pulses per minute, pulses per hour), - Low limit - value which determines amount of pulses, below which in logical channel „Lo” state will be displayed, - High limit - value which determines amount of pulses, above which in logical channel „Hi” state will be displayed, - Counting mode - defines how the device should interpret signals on pulse inputs, it has the following options: with direction input, quad 1, quad 4, - Filter - defines maximal frequency (with 50% duty cycle) the device will measure, options: disable, 10 Hz, 25 Hz, 50 Hz, 100 Hz, 1 kHz, 5 kHz, 10 kHz, 50 kHz, - Zero time - maximal awaiting time for the next pulse. If this time is exceeded the device will display 0 value; it has the following options: 0.1 sec., 1 sec., 10 sec., - Balance - submenu which contains totalizer settings: Reset now; Reset mode; Reset source; Strobe mode; Strobe source; Counting direction; Direction source. FT2 Number of inputs : 2 x pulse flow or ratemeters (isolated) + 2 x current Measurement range - Hardware limitation : flow / tacho input units: 1/sec, 1/min, 1/h current input: 0 ÷ 20 mA, 4 ÷ 20 mA current: -2 mA ÷ 30 mA Hardware resolution : Current: 1 µA Precision : 0.25% @ 25°C Internal impedance : Current: typ. 100 Ω Max input frequency : Flow / tacho: 50 kHz Protection : current: 50 mA, auto-reset fuse Sampling period : 10 ms (CMC reads modules every 100 ms) Weight : 42 g Part number : M99-FT2-001

Ek Bilgi

Ürün Kodu GM-1797/4

Ürün Etiketleri

Etiketleri ayırmak için boşluk kullanınız. Deyim tipindeki etiketler için tekli tırnak (') kullanınız.