Online Alışveriş Sitemize Hoşgeldiniz.

0(216) 466 41 47
0(530) 265 13 93

Cart:

0 item(s) - 0,00 TL
Sepetinizde hiç ürün yok.

0

Diğer Görünümler

Omron Enclosed Switch ZC-Q2155 Plunger - OK

Durumu: stokta mevcut

Only 1 left

300,00 TL

Hızlı Gözat

ÜRÜN AÇIKLAMASI : ÜRÜN SIFIR AÇIK KUTUDUR

Detaylar

Omron Enclosed Switch ZC-Q2155 Plunger atings Shape / Structure Enclosed Limit switches service life General type Operating mechanism Snap action Actuator Panel mount cross roller plunger Frequency 50/60 Hz Switching mechanism Self-reset mechanism Contact configuration Single-Pole, Double-Throw type Contact form SPDT Load General load Ratings (AC): Non-Inductive load Rated voltage: 125 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) Rated voltage: 250 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2.5 A (NC) 1.25 A (NO) Ratings (AC): Inductive load Rated voltage: 125 VAC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 250 VAC, Inductive load: 10 A (NC) 10 A (NO), Motor load: 3 A (NC) 1.5 A (NO) Ratings (DC): Non-Inductive load Rated voltage: 8 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) Rated voltage: 14 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) Rated voltage: 30 VDC, Resistive load: 6 A (NC) 6 A (NO), Lamp load: 3 A (NC) 1.5 A (NO) Rated voltage: 125 VDC, Resistive load: 0.5 A (NC) 0.5 A (NO), Lamp load: 0.4 A (NC) 0.4 A (NO) Rated voltage: 250 VDC, Resistive load: 0.25 A (NC) 0.25 A (NO), Lamp load: 0.2 A (NC) 0.2 A (NO) Ratings (DC): Inductive load Rated voltage: 8 VDC, Inductive load: 6 A (NC) 6 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 14 VDC, Inductive load: 6 A (NC) 6 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 30 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 5 A (NC) 2.5 A (NO) Rated voltage: 125 VDC, Inductive load: 0.05 A (NC) 0.05 A (NO), Motor load: 0.05 A (NC) 0.05 A (NO) Rated voltage: 250 VDC, Inductive load: 0.03 A (NC) 0.03 A (NO), Motor load: 0.03 A (NC) 0.03 A (NO) Explanation The above values indicate the steady-state current. Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current. Inrush current NC: 30 A NO: 15 A Protective circuit Classification of protection against electric shock: Class II Short-circuit protective device: 10 A fuse type gG (IEC269) Switch category: D (IEC335) Ambient temperature Operating: -10 to 80 CEL (with no icing or condensation) Ambient humidity Operating: 35 to 95%RH (with no icing or condensation) Characteristics Permissible operating speed 0.05 mm/s to 0.5 m/s Permissible operating frequency (Mechanically) 120 operations / 1 minute Max. Permissible operating frequency (Electrically) 20 operations / 1 minute Max. Contact resistance 15 mOhm Max. (Initial value) (Measuring method is contact resistance meter.) Insulation resistance Between each terminal of the same polarities: 100 MOhm Min. Between live-metallic part and ground: 100 MOhm Min. Between each terminal and non-live-metallic part: 100 MOhm Min. (at 500 VDC Megger) Dielectric strength Between each terminal of the same polarities: 1,000 VAC Between live-metallic part and ground: 2,000 VAC Between each terminal and non-live-metallic part: 2,000 VAC (50/60 Hz for 1 min) Durability (Mechanically) 10,000,000 operations Min. (No load) * When operate the actuator with the specified value of the Over Travel. (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) Durability (Electrically) 500,000 operations Min. * When operate the actuator with the specified value of the Over Travel. (Resistive load 10 A at 125 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) Pollution degree 3 (EN60947-5-1) Vibration resistance (Malfunction) Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. Shock resistance (Destruction) 1,000 m/s2 Shock resistance (Malfunction) Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2. Degree of protection IEC60529 (JEM): IP67 Applicable standard (UL) Standard No.: UL508 File number: E76675 Applicable standard (CSA) Standard No.: C22.2 NO.14 File number: LR45746 Applicable standard (TUV) Standard No.: EN60947-5-1 File number: J50041904 Applicable standard (CCC(CQC)) Standard No.: GB14048.5 File number: 2003010303077620 Applicable standard (EC Directive (Low Voltage Directive) ) 2006/95/EC Mounting specification Panel mounting, Side mounting Operating characteristics Operating Force (OF) Standard value 11.8 N Max. Release Force (RF) Standard value 4.9 N Min. Pre-Travel (PT) Standard value 1.5 mm Max. Over-Travel (OT) Standard value 3 mm Min. Movement Differential (MD) Standard value 0.2 mm Max. Operating Position (OP) Standard value 47.4 +/- 0.8 mm Product Information SWITCH, CROSS ROLLER PLUNGER Actuator Style: Cross Roller Plunger Operating Force Max: 11.8N Switch Operation: (Not Applicable) Contact Voltage AC Max: 250V Contact Voltage DC Max: 250V Contact Current AC Max: 10A Contact Current DC Max: 10A Switch Terminals: (Not Available) SVHC: No SVHC (20-Jun-2013) Actuator Type: Cross Roller Contact Configuration: SPDT External Depth: 60mm External Length / Height: 37mm External Width: 21.4mm Fixing Centres: 25.4mm No. of Electrical Operations: 750000 No. of Mechanical Operations: 10000000 Operating Force: 11.77N Operating Temperature Max: 80°C Operating Temperature Min: -10°C Pre-travel: 1.6mm Series: ZC Thermal Current Rating: 10A

Ek Bilgi

Ürün Kodu GM-2334/7

Ürün Etiketleri

Etiketleri ayırmak için boşluk kullanınız. Deyim tipindeki etiketler için tekli tırnak (') kullanınız.