Vicor V375A24C600B DC-DC Converter Module

Durumu: stokta mevcut

Only 2 left

475,00 TL

Hızlı Gözat

ÜRÜN AÇIKLAMASI : ÜRÜN SIFIR AMBALAJINDADIR

Detaylar

Vicor V375A24C600B DC-DC Converter Module

PDF DOSYASI : https://www.spezial.com/doc/vicor/alt/v375a24c600b.pdf

Category: Other Analog ICs
Manufacturer: Vicor Corporation
Description: 1-OUTPUT 600 W DC-DC REG PWR SUPPLY MODULE

SPECIFICATIONS
 
Mfr Package Description PACKAGE-9
Status ACTIVE
Technology HYBRID
Package Shape RECTANGULAR
Package Style MICROELECTRONIC ASSEMBLY
Terminal Form PIN/PEG
Terminal Finish TIN LEAD
Terminal Position DUAL
Number of Functions 1
Number of Terminals 9
Package Body Material UNSPECIFIED
Temperature Grade OTHER
Adjustable Output Yes
Input Voltage-Nom 375 V
Number of Outputs 1
Output Voltage1-Max 26.4 V
Output Voltage1-Min 2.4 V
Output Voltage1-Nom 24 V
Analog IC - Other Type DC-DC REG PWR SUPPLY MODULE
Total Power Output-Max 600 W
Input Voltage Limit-Max 425 V
Input Voltage Limit-Min 250 V
Load Regulation Coef-Max 0.2000 %
Operating Temperature-Max 100 Cel
Operating Temperature-Min -20 Cel

 

Specifications, Features, Applications

Features

RoHS Compliant (with or G pin option) DC input range: 425 V Input surge withstand: 500 V for ms DC output: 54 V Programmable output: to 110% Regulation: ±0.25% no load to full load Efficiency: to 89% Maximum operating temp: 100°C, full load Power density: 120 W per cubic inch Height above board: 0.43 in. (10,9 mm) Parallelable, with N+M fault tolerance Low noise ZCS/ZVS architecture

These DC-DC converter modules use advanced power processing, control and packaging technologies to provide the performance, flexibility, reliability and cost effectiveness of a mature power component. High frequency ZCS/ZVS switching provides high power density with low noise and high efficiency.

Parameter +In to ­In voltage PC to ­In voltage PR to ­In voltage SC to -Out voltage -Sense to -Out voltage Isolation voltage in to out in to base out to base Operating Temperature Storage Temperature Pin soldering temperature Rating -65 to Mounting torque 5 (0.57) Unit Vdc Vrms °C °F (°C) °F (°C) in-lbs (N-m) Test voltage Test voltage Test voltage M-Grade < 5 sec; wave solder < 7 sec; hand solder 6 each Notes

Applications

Off-line systems with PFC front ends, industrial and process control, distributed power, medical, ATE, communications, defense, aerospace

Output Power Pout 600 W Pin Style Blank: Short Tin/Lead L: Long Tin/Lead S: Short ModuMate N: Long ModuMate F: Short RoHS G: Long RoHS Baseplate Blank: Slotted 2: Threaded 3: Through-hole

For a description of pin options, see page 12. Baseplate options include slotted flanges, threaded and through-hole. See page 13 for dimensions. For other package sizes and power levels, see the Mini (half size) and Micro (quarter size) data sheets.

Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.

Parameter Operating input voltage Input surge withstand Undervoltage turn-on Undervoltage turn-off Overvoltage turn-off/on Disabled input current Min 250 Typ 375 Max 500 247.5 Unit Vdc mA PC pin low <100 ms Notes

Parameter Output voltage setpoint Line regulation Temperature regulation Power sharing accuracy Programming range Min Typ Max Unit % Vout nom °C % Notes Nominal input; full load; 25°C Low line to high line; full load Over operating temperature range 100% of full load Of nominal output voltage. For trimming below 90% of nominal, a minimum load 10% of maximum rated power may be required. 

+Out to ­Out, +Sense to ­Out Absolute Maximum Ratings 54 V

Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading, contact Vicor applications engineering at 800-927-9474.

Parameter Baseplate to sink; flat, greased surface Baseplate to sink; thermal pad (P/N 20265) Baseplate to ambient Baseplate to ambient; 1000 LFM Thermal capacity Min Typ Max Unit °C/Watt Watt-sec/°C

PRIMARY SIDE (PC = Primary Control; PR = Parallel) PC bias voltage current limit PC module disable PC module enable delay PC module alarm PC resistance PR emitter amplitude PR emitter current PR receiver impedance PR receiver threshold PR drive capability SECONDARY SIDE (SC = Secondary Control) SC bandgap voltage SC resistance SC capacitance SC module alarm Vdc µF Vdc With open trim; referenced to ­Sense. See Fig. 6 Referenced to ­Sense Vdc mA Vdc ms Vavg M Volts mA Volts modules 25°C Minimum pulse width: 20 ns Without PR buffer amplifier UV, OV, OT, module fault. See Figs. 2 and 4 See Fig. 2 PR load pF PC current mA PC voltage 5.5 V Must be able to sink 4 mA. See Fig. 1

Parameter Remote sense (total drop) Isolation voltage (in to out) Isolation voltage (in to base) Isolation voltage (out to base) Isolation resistance (in to out) Weight Temperature limiting Agency approvals cURus, TÜV, 9.0 (255.7) Min Typ Max 0.5 Unit Vdc Vrms M ounces (grams) °C See Figs. 2 and CSA60950-1, IEC60950-1. With appropriate fuse in series with the +Input Notes 0.25 V per leg (senses must be closed) Complies with reinforced insulation requirements Complies with basic insulation requirements Complies with operational insulation requirements

 

Ek Bilgi

Ürün Kodu GM-2494/MG3

Ürün Etiketleri